Pre-Installation Blockout |
| |
Why Use Pre-installation Blockout
This type of installation requires the LS6058-K (for LS853), LS6072-K (for LS853LED), LS6052-K (for LS853LED single colour line voltage with IP68 connector), or LS6102-K (LS853LED single colour low voltage with IP68 connector). These pre-installation kits (order separately) act as a blockout, and are intended for installation before the luminaire. This method ensures the luminaire itself is not damaged during concreting or other site works, and also allows for all wiring to be completed prior to luminaire placement. Pre-installation also allows for off-site maintenance, via the detachable IP68 connector fitted on the luminaire housing. LS6072-K (for LS853LED) uses a single gland entry instead. The mating connector on the cable has a sealing cap which ensures water does not enter the cable before the installation is completed. Pre-installation is required for all drive-over applications. | |
| |
Cable Entry Options for Pre-Installation Blockout | | Lens Options | |
 | IP68 Connector & Junction Box The luminaire is fitted with an IP68 connector, which attaches directly to the cable supplied with LS6058-K, LS6052-K or LS6102-K, without the use of any tools. The cable is 0.56 m in length, and is factory assembled with a 3 way junction box The LS640 mounting collar and the LS6072-K pre-installation kit have a single gland entry. | | | | |
| |
Cover Options for Pre-Installation Blockout |
Flush covers for pre-installation use special seals and support bushes to ensure static loads up to 4200 kg are properly supported. In order to achieve this drive-over rating, OptiClear™ or GripGlass™ must be used. |  | Pre-Installation Blockout Round Flush Cover | ■ SS316: Polished ■ SS316: Brushed |  | | |